ew 18(16): e1

Research Article

Stabilization of Electrical Parameters of Machine-Converter Voltage Source

Download1042 downloads
  • @ARTICLE{10.4108/eai.30-1-2018.153813,
        author={Yu. N. Dementyev and A. V. Glazachev and K. N. Negodin and I. Vajda and V. I. Susdorf},
        title={Stabilization of Electrical Parameters of Machine-Converter Voltage Source},
        journal={EAI Endorsed Transactions on Energy Web and Information Technologies},
        volume={5},
        number={16},
        publisher={EAI},
        journal_a={EW},
        year={2018},
        month={1},
        keywords={Machine-converter sources, synchronous generator, armature winding, asynchronous exciter, PWM autonomous inverter, cycloconverter, voltage, frequency.},
        doi={10.4108/eai.30-1-2018.153813}
    }
    
  • Yu. N. Dementyev
    A. V. Glazachev
    K. N. Negodin
    I. Vajda
    V. I. Susdorf
    Year: 2018
    Stabilization of Electrical Parameters of Machine-Converter Voltage Source
    EW
    EAI
    DOI: 10.4108/eai.30-1-2018.153813
Yu. N. Dementyev1,*, A. V. Glazachev1, K. N. Negodin1, I. Vajda1,2, V. I. Susdorf3,4
  • 1: Tomsk Polytechnic University, School of Energy & Power Engineering, av. Lenina, 30, 634050, Tomsk, Russian Federation
  • 2: Obuda University, Kando Kalman Polytechnic, Becsi ut 96/B, 1034, Budapest, Hungary
  • 3: Komsomolsk-na-Amure State Technical University, Electric Drive and Automation of Industrial Installations, av. Lenina, 27,
  • 4: 681013, Komsomolsk-na-Amure, Russian Federation
*Contact email: dementev@tpu.ru

Abstract

The paper is devoted to development of Machine-Converter Source (MCS), which forms the output voltage waveform of electric generator as sum of EMFs with near frequencies. As electric modulation generator is used a synchronous generator and asynchronous exciter that have both common driving shaft and common housing. We studied the automatic control systems for output electrical parameters of MCS when changing speed of driving shaft and load power in wide ranges.